Cooling solutions.
Start with your application.

Find the right equipment direction for high-density computing, an existing facility upgrade or a new cooling plant.

Discuss Your Project →

01  /  AI & HIGH-DENSITY COMPUTING

AI & high-density rack cooling

BEEHE in-row liquid-to-liquid CDU cabinet

In-row coolant distribution unit

Equipment reference · BEEHE

Adding GPU servers or increasing rack density changes where heat needs to be removed. Start with the server cooling interface and the facility conditions available to support it.

What to consider

Server & rack requirements — Confirm the hardware layout, heat load and available rack space.

Coolant & facility interface — Review coolant, flow, pressure drop and facility-water temperatures.

Connections & access — Plan hose routing, connector interfaces and service access.

Discuss a high-density project →

Equipment to explore

In-row liquid-to-liquid CDUs →

Transfer heat between server coolant and facility water.

BEEHE

Server cold plates & assemblies →

Explore direct-to-chip heat transfer and coolant connections.

BEEHE

02  /  EXISTING DATA CENTER FACILITIES

Cooling upgrades for existing facilities

BEEHE conventional chilled-water fan wall

Chilled-water fan wall

Equipment reference · BEEHE

Growing loads need to be assessed against the room you already have. Compare rack-level and room-level equipment around the existing layout, water supply and operational constraints.

What to consider

Rack fit & airflow — Review rack dimensions, aisle layout and server exhaust airflow.

Available cooling — Check water conditions and the room’s remaining cooling capacity.

Installation constraints — Identify access, piping routes and acceptable work windows.

Discuss a facility upgrade →

Equipment to explore

Rear-door heat exchangers →

Capture rack exhaust heat into a water circuit.

BEEHE

Fan wall cooling systems →

Explore chilled-water air cooling for data center aisles.

BEEHE

In-rack liquid-to-air CDUs →

Transfer server-loop heat to air; room cooling must remove it.

BEEHE

03  /  FACILITY COOLING & HEAT REJECTION

Data center cooling plant planning

MAGPRO air-cooled magnetic bearing centrifugal chiller, three-quarter view

Air-cooled magnetic bearing chiller

Equipment reference · MAGPRO

Start with the required supply temperature, heat load and site conditions. Chillers provide chilled water; dry coolers reject fluid heat to outdoor air, with performance tied to ambient conditions.

What to consider

Cooling duty — Define the required heat load and supply / return temperatures.

Site conditions — Review outdoor design temperature, fluid mixture and available space.

Capacity planning — Consider the project’s operating profile and expansion stages.

Discuss cooling plant requirements →

Equipment to explore

Air-cooled magnetic bearing chillers →

Provide chilled water through a refrigeration cycle.

MAGPRO

Dry coolers →

Reject fluid heat outdoors; suitability depends on the operating conditions.

BEEHE

YOUR NEXT STEP

Tell us what your project needs.

Share what you know: rack or equipment load, preferred cooling approach, project location and any site constraints. You do not need a complete specification to start the conversation.

Discuss Your Project